Adjustment data for Astra-G Z 18 XE (1.8 16V ECOTEC) 92 kW
|
Astra-G Z 18 XE (1.8 16V ECOTEC) 92 kW |
|||||||
|---|---|---|---|---|---|---|---|
| 1 | Vehicle manufacturer field no 2 | Opel | |||||
| 2 | Vehicle manufacturer code no 2 | [HSN] | 0035 | ||||
| 3 | Type and version field no 3 | T 98 | T 98 /NB | T 98 / Estate | T 98 C | ||
| 4 | Type and version code no 3 | [TSN] | Fastback | Notchback | Estate | Coupe | Convertible |
| 408 | 405 | 411 | 398 | 422 | |||
| 5.1 | Engine code / model series / model year | / DOHC / 2001 - 2004 1/2 | |||||
| 5.2 | CLCC / EGR / knock control | [yes/no] | yes/ /yes | ||||
| 5.3 | Manufacturer (mixture system) | Siemens | |||||
| 5.4 | Fuel system | Fuel injection | |||||
| 5.5 | Designation (engine management) | Simtec MS 71 | |||||
| 5.6 | Ignition system type | Direct ignition | |||||
| 5.7 | Number of cylinders / arrangement of cylinders | 4 / in-line | |||||
| 5.8 | Capacity | [cm3] | 1796 | ||||
| 5.9 | Output | [kW/rpm] | 92/5600 | ||||
| 5.10 | Octane number requirement, recommended / alternative | [RON (MON)] | |||||
| 5.11 | Tax class / emissions class (D) | Euro 3 and D4 | |||||
| 5.12 | Code No. | [SN] | 53 | ||||
| 5.13 | Tax-free months | max. until 31.12.2005 | |||||
| 5.14 | Tax rate | [Euro/100 cm 3] | 5.11 / 6.751) | ||||
| 5.15 | Tax after expiry of tax exemption | [Euro/year] | 121.50 | ||||
| 6 | Installation location diagnostic point | Centre console | |||||
| 7 | Conditioning time [sec] | min. | 30 | ||||
| 8 | Conditioning speed | [rpm] | |||||
| 9 | Engine temperature min | [°C] | 80 | ||||
| 10.1 | Idle speed, MT (min/max) | [rpm] | 710 – 930 | ||||
| 10.2 | Idle speed, AT, position "P" (min/max) | [rpm] | 710 – 930 | ||||
| 11 | Increased idle speed (min/max) | [rpm] | 2800 - 3200 | ||||
| 12 | CO increased idle speed | [% vol] | 0.3 | ||||
| 13 | Lambda increased idle speed (min/max) | 0.97 - 1.03 | |||||
| 14 | Test speed (min/max), control sensor signal | [rpm] | 710 – 930 | ||||
| 15 | Spring sensor(s) or wide band sensor(s) | S | |||||
| 16 | Min. voltage increase | [mV] | for MY 2001: 60 | from MY 2002: 300 | |||
| 17.1 | Lambda value control sensor(s) | ||||||
| 17.2 | Control sensor(s) amperage | [mA] | |||||
| 17.3 | Voltage control sensor(s) | [V] | |||||
| Nos 7 + 8 are optional fields | |||||||
| Nos 17.1-17.3 apply for wide band sensors only | |||||||